DUST V2
Part of Omnidots' environmental monitoring solution

Product Specifications

Generated at the 17th of October 2022, at 01:29:40 pm

DATA ACQUISITION

Measurement technique
Nephelometer - forward light scattering
TSP (Total Suspended Particles)
Optional cyclone filters
PM10, PM2.5, PM1 (order separately)
Measurement range
0 to 100,000 µg/m3
Measurement sensitivity
1 µg/m3
Zero calibration
Automatic zero calibration every hour or as programmed from 1 to 999 minutes
Flow rate
2.0 liters/minute ± 0.1 lpm

GPS LOCATION

Sensor type
GPS receiver
Accuracy
10 meter CEP (33 ft CEP)

LOGGING INTERVAL TIME

Range
1 - 6000 seconds

ALARM TRIGGER LEVEL

Range (concentration)
> 50 µg/m3

APPLICABLE STANDARDS

MCERTS

HONEYCOMB CLOUD SERVICE (personal dashboard)

Displays
1, 15, 30, 60 mins and 24 hour aggregates for PM 1, PM 2.5 and PM 10
Exports
1, 15, 30, 60 mins and 24 hour aggregates for PM 1, PM 2.5 and PM 10
Data storage
Secure data centre

ALARM SETTINGS

Type of message
E-mail, SMS, personal dashboard

COMMUNICATION

Wireless
WiFi

Product Specifications

MODEM

Network
- LTE / GSM

INTERNAL MEMORY

Storage
~ 2 work weeks storage of log records

AMBIENT CONDITION

Ingress protection rating
IP65
Operating temperature range
-30°C to 50°C (-22°F to 122°F)
Barometric pressure range
600 to 1040 mbar
Ambient humidity range
0 to 90% RH, non-condensing

POWER SUPPLY

Power source
External (Please specify desired mains connector)
Minimal power supply
15 - 40V DC @1.5A max.
Power consumption
~1.5A @12V

CALIBRATION

Recommended biennial (every two years)*
Certified calibration by a Omnidots certified facility
* When used according to product manual and within ambient specifications.

DIMENSIONS

Dimensions
483 x 178 x 108 mm (4.29 x 5.12 x 1.77 inch)
Weight
3.0 kg (105 oz)

ACCESSORIES

Weather Sensor, RS232 Communication Cable, RS485 Communication Cable, Cyclone PM 1 (order separately), Cyclone PM 2.5 (order separately), Cyclone PM 10